loading

Professional manufacturing and production of radiator cooling fans, condenser fans and fan motors, etc.

The design of the radiator cooling fan steps have?

As is known to all, radiator cooling fan is the use of forced convection heat, its own training effect, make the air in a certain way, by implementing the forced convection cooling mode to achieve the cooling effect. However, with the application situation and the change of environmental temperature, sometimes need different speed cooling fan to meet the demand, so a lot of manufacturers are designed to produce a variety of radiator cooling fan, so from the passage we know how to heat the cooling fan wiring, the small make up is to introduce the design steps of the radiator cooling fan. Radiator cooling fan design steps: step one: the design of the radiator cooling fan first, the relationship between the air volume and air pressure measurement, measuring the characteristics of air flow is very difficult, there are two ways of method used to measure the static pressure and air volume, one for the wind tunnel test, another way for the box. Air volume and static pressure feature specification is double box method is used to measure, the variable air exhaust system using double box method to adjust the air density, moment to open the nozzle will cause instantaneous changes of the static pressure and air volume, and then reads each hydrostatic pressure reading on the meter. In the operation of the standard atmosphere and fixed under the conditions of voltage and frequency, static pressure airflow volume as the performance of function. Static efficiency of radiator cooling fan is equal to the volume of air volume multiplied by the static pressure divided by the input of electricity. Radiator cooling fan is including motor, fan and casing outside, so the efficiency including the motor efficiency of motor, and the door leaf and frame of air flow efficiency. Step 2: all the system impedance/radiator cooling fan system characteristic curve of air flow, air flow in the flow path can meet system internal parts, the impedance will limit the free flow of air. The change of pressure is measured by static pressure, expressed in inches of water column. Each tank platoon in order to confirm the wattage, cooling system design or manufacturer must have not only effective heat dissipation of radiator cooling fan fan characteristic curve to determine the maximum air volume, and must know wind resistance curve of the system. System of internal parts can cause the loss of air pressure. The loss due to the air volume change, known as the system impedance. In addition, the cooling system operating point are characteristics of the cooling fan and cooling fan characteristic curve intersection point, called the system operating point, the working point is the optimal operation point of radiator cooling fan. In the working point, the change of the radiator cooling fan slope to a minimum, and system characteristic curve of the change rate is the lowest. Pay attention to the radiator cooling fan static efficiency ( Airflow by air pressure present electricity) For the optimization. Design steps of the radiator cooling fan will be here to share, in addition, we also pay attention to keep the air in the design of flow is not blocked, as far as possible into the outlet tuyere and unblocked, heat dissipation of the cooling fan guide vertical airflow through the system, to ensure that the air flow is smooth and enhance cooling efficiency.

GET IN TOUCH WITH Us
recommended articles
knowledge Info Center
Many of our low-demand customers often go to the electronics market or the so-called wholesale department to buy cooling fans.

Automobile radiator fan factory is a cooling fan manufacturer integrating Ru0026D, production and sales.
Recently, we dealt with a case of changing the installation method of the cooling fan, which has a great impact on the cooling fan.

During normal use of any electronic product, due to the effect of current, there will be varying degrees of temperature rise inside the device, and when the temperature rise of the device exceeds a certain range, its life will be attenuated to varying degrees (for a long time, The safety of equipment operation will also be reduced).
Car cooling fan working position and its principle: cooling fan working principle 1.

The comprehensive laboratory of the automobile radiator fan factory has introduced new equipment-the thermal shock test box.
The commonly used cooling fan voltage is generally 12V, but some customers' products, such as temperature-controlled cooling fans, set a lower voltage for the cooling fan at low temperatures.
When we choose a cooling fan, especially for certain voltages that are not very stable or have several different voltage gears for speed adjustment, we need to understand the voltage range of the cooling fan, such as a cooling fan that works with a 12V DC voltage.
no data
Ready to work with us ?
Find us here: 
After nearly 20 years of hard work, the factory has grown from an unknown family workshop to an industry leader with a complete management system and independent research, development and manufacturing capabilities.
Contact us
Tel: +86 - 576-8625 9388 
Fax: +86 - 576 - 8625 9008

Address:
No. 58-11, Jintang North Road, East Wenling New District, Taizhou City, Zhejiang Province, China
Copyright © 2025 TONGCHI | Sitemap| Privacy Policy
Customer service
detect