Will the 12V cooling fan be damaged if the voltage is lower than the rated voltage?

The commonly used cooling fan voltage is generally 12V, but some customers' products, such as temperature-controlled cooling fans, set a lower voltage for the cooling fan at low temperatures. At present, when the voltage is low, the speed of the cooling fan is slower and more Be quiet. In order to design three different grades of air volume, some customers design three different voltages below 12V, so the cooling fan that does not work within the rated voltage range will be damaged if it is used for a long time. Generally, the cooling fan working at 12V, as long as the supplier can ensure that it can work normally under low voltage, can ensure smooth start-up and operation, the voltage is lower than 12V, there is no problem, such as a high-speed 12V cooling fan, the voltage can be as low as 5V, or even 4.5 V can work, and the sound is quieter at this time, but the 12V cooling fan cannot use 10% higher than its rated voltage, such as 13.2V. It may exceed the power and cause the cooling fan to burn out, especially some high air volume and high speed. If it is possible that the cooling fan is higher than the rated voltage, you can provide the cooling fan supplier with this requirement to expand the voltage range. Welcome to the heat dissipation classroom and news center of the cooling fan manufacturer again. The copyright belongs to the cooling fan manufacturer and represents only personal opinions. Please do not reprint the whole article. Any violation will be held for legal responsibility. If you need to know more about the cooling fan manufacturer's product introduction, please Click Product Center

GET IN TOUCH WITH Us
recommended articles
knowledge Info Center
Many of our low-demand customers often go to the electronics market or the so-called wholesale department to buy cooling fans.

Automobile radiator fan factory is a cooling fan manufacturer integrating Ru0026D, production and sales.
Recently, we dealt with a case of changing the installation method of the cooling fan, which has a great impact on the cooling fan.

During normal use of any electronic product, due to the effect of current, there will be varying degrees of temperature rise inside the device, and when the temperature rise of the device exceeds a certain range, its life will be attenuated to varying degrees (for a long time, The safety of equipment operation will also be reduced).
Car cooling fan working position and its principle: cooling fan working principle 1.

The comprehensive laboratory of the automobile radiator fan factory has introduced new equipment-the thermal shock test box.
When we choose a cooling fan, especially for certain voltages that are not very stable or have several different voltage gears for speed adjustment, we need to understand the voltage range of the cooling fan, such as a cooling fan that works with a 12V DC voltage.
Customers require a large air volume for the cooling fan.
no data
Ready to work with us ?
Find us here: 
After nearly 20 years of hard work, the factory has grown from an unknown family workshop to an industry leader with a complete management system and independent research, development and manufacturing capabilities.
Contact us
Tel: +86 - 576-8625 9388 
Fax: +86 - 576 - 8625 9008

Address:
No. 58-11, Jintang North Road, East Wenling New District, Taizhou City, Zhejiang Province, China
Copyright © 2025 TONGCHI | Sitemap| Privacy Policy
Customer service
detect