loading

Professional manufacturing and production of radiator cooling fans, condenser fans and fan motors, etc.

Principles to reduce the noise of cooling fans

We have already mentioned that the cooling fan will have a certain amount of noise, as long as it is within a reasonable noise range, it will not affect the normal use of the fan. But what if the normal noise is exceeded? Today Tongchi will tell you how to reduce the noise of the cooling fan in principle.

u003cbru003e

u003cbru003e

u003cbru003e

u003cbru003e

u003cbru003e

u003cbru003e Noise reduction method one: system impedance

u003cbru003e

u003cbru003e

u003cbru003e The range between the air inlet and outlet of a chassis accounts for 60% to 80% of the total system impedance. In addition, the greater the airflow, the higher the noise of the cooling fan. The higher the system impedance, the greater the airflow required for cooling, so in order to minimize noise, the system impedance must be minimized.

u003cbru003e

u003cbru003e

u003cbru003e Noise reduction method 2: Air flow disturbance

u003cbru003e

u003cbru003e

u003cbru003e The turbulence caused by the obstacles encountered along the air flow path will cause noise. Therefore, any obstruction to the cooling fan, especially in the critical air inlet and outlet range, must be avoided to reduce noise.

u003cbru003e

u003cbru003e

u003cbru003e Noise reduction method three: fan size

u003cbru003e

u003cbru003e

u003cbru003e Since high-speed fans produce more noise than low-speed fans, you should try and choose low-speed fans as much as possible. A fan with a larger size and a lower speed is usually quieter than a fan with a smaller size and a higher speed when delivering the same air volume.

u003cbru003e

u003cbru003e

u003cbru003e Noise reduction method 4: temperature rise

u003cbru003e

u003cbru003e

u003cbru003e In a system, the air volume required for cooling is inversely proportional to the allowable temperature rise. The fan allows a slight increase in temperature rise, which can greatly reduce the required air volume. Therefore, if the restrictions imposed on the allowable temperature rise are slightly relaxed, the required air volume will be reduced and the noise will also be reduced.

u003cbru003e

u003cbru003e

u003cbru003e Noise Reduction Method 4: Isolate Vibration

u003cbru003e

u003cbru003e

u003cbru003e In some cases, when the weight of the entire system is very light, or the system must operate in a certain manner, it is particularly recommended to use soft insulation equipment to avoid the transmission of fan vibration.

u003cbru003e

u003cbru003e

u003cbru003e Noise reduction method five: voltage fluctuation

u003cbru003e

u003cbru003e

u003cbru003e Voltage fluctuations will affect the noise level. The higher the voltage of the fan, the greater the vibration and the greater the noise due to the increase in speed. Therefore, if the air volume is available, try to choose a fan with a lower voltage.

u003cbru003e

u003cbru003e

u003cbru003e

u003cbru003e

u003cbru003e

u003cbru003e When your fan is noisy, try the above methods. The AC cooling fan and the DC cooling fan are the same. As long as the method is used for your fan, the noise can reach the normal level.

GET IN TOUCH WITH Us
recommended articles
knowledge Info Center
Many of our low-demand customers often go to the electronics market or the so-called wholesale department to buy cooling fans.

Automobile radiator fan factory is a cooling fan manufacturer integrating Ru0026D, production and sales.
Recently, we dealt with a case of changing the installation method of the cooling fan, which has a great impact on the cooling fan.

During normal use of any electronic product, due to the effect of current, there will be varying degrees of temperature rise inside the device, and when the temperature rise of the device exceeds a certain range, its life will be attenuated to varying degrees (for a long time, The safety of equipment operation will also be reduced).
Car cooling fan working position and its principle: cooling fan working principle 1.

The comprehensive laboratory of the automobile radiator fan factory has introduced new equipment-the thermal shock test box.
The commonly used cooling fan voltage is generally 12V, but some customers' products, such as temperature-controlled cooling fans, set a lower voltage for the cooling fan at low temperatures.
When we choose a cooling fan, especially for certain voltages that are not very stable or have several different voltage gears for speed adjustment, we need to understand the voltage range of the cooling fan, such as a cooling fan that works with a 12V DC voltage.
no data
Ready to work with us ?
Find us here: 
After nearly 20 years of hard work, the factory has grown from an unknown family workshop to an industry leader with a complete management system and independent research, development and manufacturing capabilities.
Contact us
Tel: +86 - 576-8625 9388 
Fax: +86 - 576 - 8625 9008

Address:
No. 58-11, Jintang North Road, East Wenling New District, Taizhou City, Zhejiang Province, China
Copyright © 2025 TONGCHI | Sitemap| Privacy Policy
Customer service
detect